Table 8-213. DIG-IP-STN Digital IP Station Error Log Entries — Continued
Error
Aux
Type
Data
Associated Test
1537 (h)
40968
2305 (i)
Any
None
2817 (j)
Station Hyperactivity
Notes:
a. Error Type 1—This error reports the registration status of the endpoint. If
Avaya MultiVantage ™ software claims the endpoint is registered and
receives keep-alive handshakes from the endpoint, the test passes. If
keep-alive handshaking has failed, the test fails. If the user has
intentionally un-registered from S8700 Multi-Connect, the station is now
basically an AWOH station and is no longer being maintained; no tests run
for this station.
b. Error Type 18—This error type is logged when the port/station is busied
out by maintenance personnel. Make sure the port/station is released from
busy via the release port | station command (IP terminal only).
c. Error Type 257—This error tracks failures of the signaling path PING test.
The test attempts to send a PING packet to the endpoint IP address, as
reported during registration. The PING packet originates with the C-LAN
board through which the endpoint is registered. If the PING response
packet is received, the test passes. If the PING response packet times out,
the test fails.
d. This refreshes the lamp state of every lamp on a virtual DCP station. If
successful, the update always passes. It can abort, but it never fails. This
update (test number 16) is the same one used for existing DCP stations.
e. This refreshes the ringer state on a virtual DCP station and queries the
virtual station's switch-hook state. If successful, the update always passes.
It can abort, but it never fails. This runs a subset of the entire audit update
that runs for standard DCP sets.
f. Error Type 513—This error type indicates that the terminal failed to
respond to the ID Query request. This implies that there is something
wrong with the terminal or the communication path. (IP terminal only).
g. Error Type 1281—This error type indicates that the terminal is reporting a
bad state of health (IP terminal only).
h. Error Type 1537—This error type indicates that the link has gone down
between the terminal and its gateway to the switch. This likely means that
the terminal has unregistered (IP terminal only).