Maintenance-Object Repair Procedures
Hardware Error Log Entries and Test to Clear
Values
Table 8-75. ATM D-channel Error Log entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
18 (a)
0
busyout port UUCSSpp
130 (b)
None
1793 (c)
Signaling Link Board
check (#643)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
pp is for ports 9–32.
Notes:
a. Error Type 18: D channel busied out; no calls possible over this D channel.
b. Error Type 130: circuit pack removed or has been insane for more than
11 minutes. To clear the error, reinsert or replace the circuit pack.
c. Error Type 1793: ATM Trunk circuit pack failed the Signaling Link Board
check (#643). Resolve any ATM-TRK errors in the Error Log.
System Technician-Demanded Tests:
Descriptions and Error Codes
The command to test the ATM-DCH MO is test port UUCSSpp, where pp is for
ports 9-32.
Table 8-76. System Technician-Demanded Tests: ATM-DCH
Order of Investigation
Signaling Link Board check (#643)
1.
D = Destructive, ND = Nondestructive
8-184
Issue 1 May 2002
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
ON
Continued on next page
Short Test
Long Test
Sequence
Sequence
X
X
Test to Clear Value
2
test port UUCSSpp
release port UUCSSpp
test port UUCSSpp
test board UUCSS l
1
D/ND
ND