ATM-TRK (Circuit Emulation Service Circuit Pack)
Table 8-125. ATM Board Reset (#1256)
Error
Test
Code
Result
Description / Recommendation
1005
ABORT
Wrong circuit pack configuration to run this test. The ATM CES Trunk Interface
circuit pack provides timing for the system and cannot be reset without major
system disruptions.
1. Set synchronization to another ATM CES trunk circuit pack or to the
1015
ABORT
Test cannot be run because the ATM-TRK circuit pack has not been busied
out.
1. Busyout out the circuit pack (busyout board UUCSS).
2. Repeat the test (test board UUCSS long).
None
ABORT
Could not allocate the required system resources
1. Retry the command up to 5 times at 1-minute intervals.
2. If the test continues to abort escalate the problem.
2000
ABORT
Sanity test timed out.
1. Wait 5 minutes. Then see if ATM-TRK circuit pack is visible to the system
2. If the ATM-TRK circuit pack is visible (list configuration all), run the test
3. If the ATM-TRK circuit pack is not visible to the system (list configuration
4. If the ATM-TRK circuit pack is still not recognized by the system, replace
2100
ABORT
Could not allocate required system resources
1. Retry the command up to 5 times at 1-minute intervals.
2500
ABORT
Internal system error
1. Try to reset the circuit pack (reset board UUCSS).
1
FAIL
The circuit pack failed to reset
2
FAIL
The circuit pack failed to restart.
1. Retry command.
2. If the problem persists, replace the ATM-TRK circuit pack.
555-233-143
Tone-Clock circuit pack and test again.
by running list configuration all.
again, and escalate if the problem recurs.
all), re-seat the ATM-TRK circuit pack, and retest.
the board.