E-DIG-STA (Emulated Digital Line)
Table 8-284. Test #13 Voice and Control Channel Local Loop Test — Continued
Error
Test
Code
Result
Description / Recommendation
7
FAIL
Conference test failed on primary channel. In some cases, users may not
notice disruption in service. In extreme cases, conferencing feature may not
work at all.
14
FAIL
The primary voice channel is not transmitting properly. User impact may range
from noticing nothing to not being able to use this port.
15
FAIL
The control channel between the Processor and Digital circuit pack is not
transmitting properly. User impact may range from noticing nothing to not
being able to use the port. This could disrupt other users.
16
FAIL
The secondary voice channel is not transmitting properly. User impact may
range from noticing nothing to not being able to use this port.
1. Run circuit pack tests to check the Tone Generator circuit pack and the
2. Resolve any problems that are detected on the Tone Generator circuit pack
3. If the test still fails, replace the Digital Line circuit pack.
PASS
The test passed, and every channel is transmitting properly.
1. To ensure that this is not an intermittent problem, repeat this test up to 10
2. If noisy connections for voice or corrupted data for data transfer persist,
555-233-143
Tone Detector circuit pack using the test board UUCSSpp command.
or Tone Detector circuit pack.
times.
examine the station, connections, and wiring.
Continued on next page
Issue 1 May 2002
8-733

Advertisement

Table of Contents
loading

Table of Contents