Maintenance-Object Repair Procedures
Conference Circuit Test (#7)
The Conference Circuit test verifies that the NPE channel for the port being tested
can correctly perform the conferencing function. The NPE is instructed to listen to
several different tones and conference the tones together. The resulting signal is
then measured by a tone detector port. If the level of the tone is within a certain
range, the test passes.
Table 8-229. Test #7 Conference Circuit Test
Error
Test
Code
Result
Description / Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
in use on a valid call.
1. Use the status station or status trunk command to determine when the
1004
ABORT
The port has been seized by a user for a valid call.
1. Use the status station or status trunk command to determine when the
2. Retry the command at 1-minute intervals up to 5 times.
1018
ABORT
Test disabled via administration. This only applies to analog stations.
1. To enable test, set the
1020
ABORT
The test did not run due to a previously existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
8-568
Issue 1 May 2002
port is available for testing.
port is available for testing.
Test
the command.
and attempt to diagnose the previously existing error.
field (change station extension) to y. Use
Continued on next page