Maintenance-Object Repair Procedures
Table 8-276. Test #790 DS1 Facilities Connectivity Loop-Back Test — Continued
Error
Test
Code
Result
Description / Recommendation
FAIL
TN574 DS1 facilities connectivity loop-back test failed.
1
FAIL
TN1654 near-end DS1 facility A is connected to far-end DS1 facility B.
2
FAIL
TN1654 near-end DS1 facility A is connected to far-end DS1 facility C.
3
FAIL
TN1654 near-end DS1 facility A is connected to far-end DS1 facility D.
10
FAIL
TN1654 near-end DS1 facility B is connected to far-end DS1 facility A.
12
FAIL
TN1654 near-end DS1 facility B is connected to far-end DS1 facility C.
13
FAIL
TN1654 near-end DS1 facility B is connected to far-end DS1 facility D.
20
FAIL
TN1654 near-end DS1 facility C is connected to far-end DS1 facility A.
21
FAIL
TN1654 near-end DS1 facility C is connected to far-end DS1 facility B.
23
FAIL
TN1654 near-end DS1 facility C is connected to far-end DS1 facility D.
30
FAIL
TN1654 near-end DS1 facility D is connected to far-end DS1 facility A.
31
FAIL
TN1654 near-end DS1 facility D is connected to far-end DS1 facility B.
32
FAIL
TN1654 near-end DS1 facility D is connected to far-end DS1 facility C.
55
FAIL
TN1654 DS1 CONV packet facility is down and can't send loop-up message to
the far end.
1. Enter display errors and follow the associated repair procedures for any
2. Check the DS1 connections, both circuit packs should have their DS1
3. Check the DS1 Converter Measurements Report to see if there are
4. Both circuit packs may not have the same translation information. Run the
PASS
DS1 facility connections are correct.
0
NO
The system software found no board.
BOARD
1. Reset the board.
2. Remotely retry the command.
8-714
Issue 1 May 2002
DS1-FAC errors on the DS1 facilities at both ends of the DS1 CONV
complex. If an alarm exists on a DS1 facility, then this test will fail.
facilities connected identically.
facilities with excessive errors, execute command list measurements
ds1-facility summary. If there are facilities with excessive errors, execute
the Far-End Internal Loopback test (#797) via the test ds1-facility
UUCSSf long command on those facilities, and follow repair procedures
described for the test.
Board Options Audit test (#795) via the test board UUCSS short
command for both circuit packs in the DS1 CONV complex to send the
options, and check the results of this audit test. This test will not pass until
the audit test problems are resolved.