Maintenance-Object Repair Procedures
Table 8-176. Test #42 Tone Detection Verification Test — Continued
Error
Test
Code
Result
Description / Recommendation
1-3
FAIL
DTMF digits were not detected correctly. This may or may not impact reception
of R2-MFC calls.
1. Run the short test sequence via the test port UUCSSpp sh r 1 command.
2. If the problem persists, the system is still operating properly but capacity
102
FAIL
2225-Hz Modem Answer tone was not detected correctly. This will impact
call-classification operation.
1. Run the short test sequence via the test port UUCSSpp sh r 1 command.
2. If the problem persists, the system can still operate properly but capacity
130
FAIL
Forward or backward R2-MFC signals were not correctly generated or
detected. This will impact R2-MFC calls.
1. Run the short test sequence via the test port UUCSSpp sh r 1 command.
2. If the problem persists, the system can still operate properly but capacity
PASS
Tone detection verification is successful. The call classifier port is able to
detect and generate every necessary tone.
8-432
Issue 1 May 2002
will be reduced. To restore performance to normal, replace the call
classifier circuit pack containing the defective CLSFY-PT (Call Classifier
Port).
will be reduced. In order to restore performance to normal, replace the call
classifier circuit pack containing the defective port.
will be reduced. In order to restore performance to normal, replace the call
classifier circuit pack containing the defective port.