Maintenance-Object Repair Procedures
Table 8-129. ATM Board Framer Loop-Around Test (#1260) — Continued
Error
Test
Code
Result
Description / Recommendation
6
FAIL
A previously established loop around was not released.
1. Run reset board UUCSS.
2. Retry the command up to 3 times at 1-minute intervals.
3. If this test continues to fail, replace the ATM-TRK circuit pack.
4. Rerun test board UUCSS long.
PASS
The non-optical parts of the ATM-TRK circuit pack are functioning properly.
0
NO
ATM-TRK circuit pack not found
BOARD
1. Check the error log for Error 125 (wrong board) or Error 131 (no board),
2. Check that the board is properly translated and inserted.
3. Check for Error 1538 (hyperactivity), and run reset board UUCSS if
4. Rerun test board UUCSS long.
5. If the test fails, replace the board, and rerun test board UUCSS long.
8-296
Issue 1 May 2002
and correct as necessary.
necessary.
Continued on next page