Adx16A-Pt (Audix Analog Line/Control Link) - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
ADX16A-PT (AUDIX Analog
Line/Control Link)
MO's Name (in
Alarm
Alarm Log)
Level
ADXCL-PT or
MINOR
ADX16A-PT
ADXCL-PT or
WARNING
ADX16A-PT
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21). pp is the 2-digit port number
(01, 02,...).
!
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow the
instructions on the TN566/TN2169 faceplate:
Remove EMBEDDED AUDIX circuit packs
Cycle power to a carrier containing EMBEDDED AUDIX circuit packs
Remove power to a carrier containing EMBEDDED AUDIX circuit packs
The ADX16A-PT MO represents a port on a TN566/TN2169 EMBEDDED AUDIX
circuit pack that is operating in control-link (CL) mode. For circuit-pack-level
problems (ADX16A-BD or ANL-16-BD), see
Pack)'' on page
digital-port mode, see:
''ADX8D-PT (AUDIX Digital Port)'' on page 8-16
''ADX16D-P (16-Port AUDIX Digital Port)'' on page 8-26
The tests described in this section apply only to switch-side maintenance that
tests a circuit pack's components related to the TDM-bus interface. The AUDIX
system has an extensive maintenance strategy that is described in EMBEDDED
AUDIX System Maintenance, 585-300-110.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction
board (MFB) and the TN2169 Alarm board (ALB). Because of its size this
combination occupies 5 slots, but only 1 slot is functional as far as the switch is
concerned. The other 4 slots are seen by the switch as "AUDIX-reserved" slots.
In CL mode the TN566 pack supports up to 16 voice ports. When a call to a
station with an AUDIX login is not answered, AUDIX answers the call using one of
the available voice ports.
Unlike other AUDIX systems, EMBEDDED AUDIX is not an adjunct.
8-34
Issue 1 May 2002
Initial Command to
1
Run
test port UUCSSpp l
test port UUCSSpp sh
8-1872. For port-level problems with AUDIX operating in
Full Name of MO