Avaya S8700 Maintenance Manual page 1344

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-250. Test #143 Minor Alarm Inquiry Test — Continued
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and one or more of
the following symptoms may be exhibited.
1. The DS1-BD tests (such as test 138 and test 139) are aborting with error
2. The tests run on the ports of this circuit pack are returning a no board
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the ports are
FAIL
The DS1 Interface circuit pack detects a Minor alarm. The DS1 bit error rate is
greater than 1/1,000,000 and less than 1/1000.
1. The performance of DS1 link between DS1 Interface circuit pack and
2. Verify that both endpoints of the DS1 link are administered using the same
3. If the DS1 interface circuit pack connects to a T1 facility, call the vendor of
4. Check the physical connection of the DS1 pack and of the cable.
5. If this continues to fail, escalate this problem.
8-622
Issue 1 May 2002
code 2000.
result.
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the system,
and all of its trunks are placed into the out-of-service state. The system
will try to restore the circuit pack within 15 minutes. When no faults are
detected for 15 minutes, the DS1 interface circuit pack is restored to
normal operation. Every DS1 interface trunk is then returned to the
in-service state. Hyperactivity is often caused by the associated facility.
In such a case, faults (such as slips, misframes, or blue alarms) would
be entered in the error log. In addition, many hardware errors would be
logged against the associated trunk circuits. If the facility is OK and the
error occurs again after 15 minutes, escalate this problem.
remote DS1 endpoint is poor. If DS1 Interface circuit pack is TN767, enter
list measurement ds1-log UUCSS command to read the error seconds
measurement.
signaling mode, framing mode, and line coding.
the T1 carrier to diagnose the remote DS1 endpoint. If the DS1interface
circuit pack connects directly to a switch, call the system technician of the
remote switch to diagnose the DS1 endpoint.
Continued on next page
555-233-143