Maintenance-Object Repair Procedures
Table 8-260. Test #1215 Inject Single Bit Error Test — Continued
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and one or more of
the following symptoms may be exhibited.
1. The DS1-BD tests (such as test 138 and test 139) are aborting with error
2. The tests run on the ports of this circuit pack are returning a no board
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the ports are
PASS
A single bit error has been successfully injected into an active framed 3-in-24
test pattern.
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Use the add ds1 UUCSS
2. If board was already administered correctly, check the error log to
3. If the board was found to be correctly inserted in step 1, issue the busyout
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
8-654
Issue 1 May 2002
code 2000.
result.
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the system,
and all of its trunks are placed into the out-of-service state. The system
will try to restore the circuit pack within 15 minutes. When no faults are
detected for 15 minutes, the DS1 interface circuit pack is restored to
normal operation. Every DS1 interface trunk is then returned to the
in-service state. Hyperactivity is often caused by the associated facility.
In such a case, faults (such as slips, misframes, or blue alarms) would
be entered in the error log. In addition, many hardware errors would be
logged against the associated trunk circuits. If the facility is OK and the
error occurs again after 15 minutes, escalate this problem.
command to administer the DS1 interface if it is not already administered.
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
board command.
This should re-establish the link between the internal ID and the port.