AN-LN-PT (Analog Line Port)
Table 8-44. Test #48 Station Present Test — Continued
Error
Test
Code
Result
Description / Recommendation
1008
ABORT
A ringing circuit could not be allocated. Either every ringing circuit is active, the
ringing generator is defective, or it is incorrectly wired.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error Log.
3. If ABORT 1008 occurs for this test on other circuit packs as well, the
4. If an ABORT 1008 does not occur on other ports, then all four ring phases
1018
ABORT
Administration has disabled the test. The default for the
station form is y. Determine why this field has been set to n on this station (this
may be due to the ringing application Test 48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
2. Change the
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
FAIL
The terminal equipment is not connected to the circuit pack. Some terminal
equipment, such as modems, may fail even when connected properly.
1. Remotely test the terminal equipment.
2. If the test fails again, resolve any RING-GEN errors in the error log, if
3. Check all of the wiring between the station equipment and the switch.
4. If the test still fails, the terminal equipment may be defective. Check and
5. Some terminal equipment might fail even when it is connected properly. If
555-233-143
ringing generator may be defective or is incorrectly wired (see
''RING-GEN'' on page
8-1357.
are active.
station extension.
field on the station form to y.
Test?
present.
Then, run the test again.
replace it, if necessary.
this is the case, disable the test using the change station extension
command (enter n into the
Tests 6, 7, 35, and 161 on this port.
Test
field). Note that this action also disables
Continued on next page
Issue 1 May 2002
Test?
field on the