Maintenance-Object Repair Procedures
Table 8-357. Test #62 Hybrid Line Ringer Update Test — Continued
Error
Test
Code
Result
Description / Recommendation
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
2. If the board was found to be correctly inserted in step 1, issue the busyout
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
8-924
Issue 1 May 2002
config command, and resolve any problems that are found.
board command.
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Continued on next page