BRI-SET, ASAI-ADJ, BRI-DAT
Table 8-154. ISDN-BRI CAUSE VALUES — Continued
Error
Code
Test Result
50
Requested
Facility Not
Subscribed
58
Bearer
Capability Not
Currently
Available
65
Bearer Service
Not
Implemented
555-233-143
Description / Recommendation
Requested facility is implemented, but not administered.
Potential administration problem with endpoint or adjunct.
For BRI endpoints:
1. Verify the switch administration of endpoint using either
the display station or display data-module
commands.
2. If step 1 does not resolve the problem, refer to the
endpoint's service manual and verify administration on
the endpoint.
3. If step 2 does not resolve the problem, escalate to the
next tier.
For ASAI adjuncts:
1. Display the Customer Optional Features Form
(administration screen) on the switch to determine which
ASAI capabilities are turned on in the switch.
2. Verify that the adjunct is administered to support the
identical capabilities as the switch. If there is a
mismatch in the administered capabilities, then
re-administer the switch and/or the adjunct to establish a
consistent set of desired capabilities on both the switch
and the adjunct.
3. If step 2 does not resolve the problem, escalate to the
next tier.
For Avaya adjuncts:
1. Display the Customer Optional Features Form
(administration screen) on the switch to determine
whether the Avaya adjunct is set enabled on in the
switch.
2. If error type 2567 or 2568, verify the Avaya adjunct
version, and re-administer if needed.
3. If step 2 does not fix the problem, escalate to the next
tier of support
Requested bearer capability is implemented, but not
administered. No B channel is administered. See
recommendation 50 above.
Requested service not implemented in switch or endpoint.
Continued on next page