Avaya S8700 Maintenance Manual page 1037

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

AUX-TRK (Auxiliary Trunk)
Looparound and Conference Test (#33)
This test checks the reflective loop around and conference capabilities of an
auxiliary trunk port circuit. The test uses 404-Hz, 1004-Hz, and 2804-Hz tones.
Each tone is separately transmitted through the loop and checked. All of these
tests are performed on-board.
Table 8-137. Test #33 Looparound and Conference Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
2. Retry the command at 1-minute intervals up to 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the trunk
2. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7
FAIL
The conference capabilities of the port failed.
1. If no service problems exist on the port, continue to use the port until the
555-233-143
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle.
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle.
circuit pack can be replaced.
Continued on next page
Issue 1 May 2002
8-315

Advertisement

Table of Contents
loading