Avaya S8700 Maintenance Manual page 1541

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

EXP-INTF (Expansion Interface Circuit Pack)
Table 8-311. Test #224 Expansion Interface Test — Continued
Error
Test
Code
Result
Description / Recommendation
5001
FAIL
Initialization failure: the EI circuit pack reset successfully and restarted
execution, but the EI circuit pack could not synchronize itself during hardware
initialization.
1. Issue the reset board PCSS command. If the circuit pack is in the active
2. If the reset fails with the same error code, execute the test tone-clock PC
3. If the EI circuit pack still fails to reset with the same error code, replace the
5002
FAIL
Initialization failure: EI circuit pack reset successfully and restarted
execution. But the EI circuit pack has determined that a lightwave transceiver
was not attached to the backplane connector when the EI circuit pack was last
reset. If this system does not have duplicate EI links, every user in the PN will
be without service until this problem is resolved. If this system does have
duplicate links, the backup EI link is unavailable until this problem is resolved.
1. Attach lightwave transceiver to 25-pair backplane connector in slot
2. Reset the circuit pack again.
3. If the reset fails with an Error Code other than 5002, refer to the
4. If the reset fails again with Error Code 5002, replace the lightwave
5. If the reset fails again with Error Code 5002, the new lightwave transceiver
555-233-143
link, this procedure can be very destructive. If a test board PCSS shows
every test passing, and there is no standby link to which you can switch,
perform this reset at a time when service is least disrupted by losing use of
the PN.
command where P is the network that contains this EI circuit pack and C is
the carrier that contains the active Tone-Clock on network P. Also look for
SYNC and TONE-BD errors. Resolve any SYNC and TONE-BD errors by
following the Maintenance documentation for these MOs. Then reissue
the reset board PCSS command.
EI circuit pack.
belonging to EI circuit pack.
appropriate maintenance section.
transceiver, reset the circuit pack, and execute the reset board PCSS
command again.
may be defective, or the EI circuit pack may need to be replaced.
Continued on next page
Issue 1 May 2002
8-819

Advertisement

Table of Contents
loading