ETH-PT (Control LAN Ethernet)
Error Log Entries and Test to Clear Value
Table 8-290. ETH-PT Error Log Entries
Aux
Error Type
Data
1
0
0
1 (a)
0
513 (b)
0
769 (c)
0
1281 (d)
0
1537, 1538 (e)
1793–1920 (f)
2305–2560 (g)
2561–2816 (g)
3329 (h)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. Error Type 1—Ethernet Local Looparound test (#1278) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to repair procedures for Test #1278.
b. Error Type 513—Link Integrity Inquiry test (#1282) failed, or C-LAN port
detected loss of Ethernet link integrity.
Possible causes:
1. Test the port (test port UUCSSpp long).
2. If the Link Integrity Inquiry test (#1282) fails, refer to its repair
555-233-143
Associated Test
Any
Ethernet Local
Looparound test
(#1278)
Link Integrity Inquiry
(#1282)
Session Status test
(#1286)
TCP/IP Ping test
(#1281)
Cabling
Ethernet transceiver
procedure.
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test port UUCSSpp s
MINOR
ON
test port UUCSSpp l r
3
MINOR
OFF
test port UUCSSpp r 2
WARNING
OFF
MINOR
OFF
WARNING
OFF