Avaya S8700 Maintenance Manual page 1058

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
h. Error Type 1793 – This error occurs when the BRI Port Local TDM Loop
Around test (#619) fails. Run the long test sequence, and pay particular
attention to the results of Test #619.
There are no Test to Clear Values for the following error types. The error
types are simply provided as additional data that may prove useful while
troubleshooting.
i. Error Type 3841 – This error occurs when a Layer 1 Transmission error is
detected for the port. Run the long test sequence, and pay particular
attention to the results of the Layer 1 Transmission Error Counter test
(#624).
j. Error Type 3842 – A BRI port supports up to three Terminal Endpoint
Identifiers (TEIs). This error occurs when the switch receives a request for
a fourth TEI on a port. Check the number of endpoints administered for
this port.
k. Error Type 3843 – This error occurs when an SPID initialization request is
made from an endpoint and the switch determines that the SPID value is
invalid or is a duplicate of another SPID that is already initialized at Layer 3
on the port. Check the administration of the endpoints.
l. Error Type 3844 – This error occurs when the circuit pack detects an
overflow of its receive buffers. Run the long test sequence, and pay
particular attention to the results of the Receive FIFO (First In First Out)
Overflow Error Counter test (#625).
m. Error Type 3845 – This error occurs when the BRI Port Local LAN Loop
Around test (#618) fails. Run the long test sequence, and pay particular
attention to the results of Test #618.
n. Error Type 3846 – This error most likely occurs when the Terminal
Endpoint Identifier (TEI) administered for the ASAI or Avaya endpoint does
not match the TEI administered in the ASAI or Avaya adjunct. Check the
switch administration of the TEI against that of the adjunct and make sure
that both are using the same TEI.
o. Error Type 3847 – Indicates that sets on the port do not support layer-3
initialization. Consult the Service Set documentation.
8-336
Issue 1 May 2002
555-233-143

Advertisement

Table of Contents
loading