INADS (INADS Link)
Table 8-358. INADS Link Test Error Log Entries
Error
Test
Code
Result
Description / Recommendation
1
0
A test call was successfully placed to the alarm receiver. No trouble found.
2
0
Informative error indicating that alarm origination was disabled at the time of
the test. The test runs even though alarm origination is disabled.
1. If desired, enable Alarm Origination via the Maintenance-Related System
2. Repeat the test.
3
0
The alarm receiver's connection is currently in use.
1. Wait 10 minutes, and retry this command.
4
0
The alarm receiver did not answer the test call.
1. Verify that the alarm receiver is up and running.
2. Verify the accuracy of the alarm receiver's phone number and the system's
3. Enable alarm origination via the Maintenance-Related System Parameters
4. Retry the command.
5
0
The alarm receiver's phone number is not assigned.
1. Assign the alarm receiver's phone number via the Maintenance-Related
2. Retry the command.
6
0
The alarm receiver did not return an acknowledgment for the "test inads alarm"
message.
1. Verify the accuracy of the alarm receiver's phone number and the system's
2. Verify that the alarm receiver is up and running.
3. Retry the command.
7
0
The alarm receiver returned a negative acknowledgment for the "TESTING
INADS LINK" message.
1. Verify that the product IDs match in the customer's switch and the alarm
2. Rerun the test.
555-233-143
Parameters form.
product ID using the Maintenance-Related System Parameters form.
form.
Test the SYSAM (System Access Maintenance) by issuing the test
maintenance a | b command.
System Parameters form.
product ID via the Maintenance-Related System Parameters form.
receiver's database. Use the Maintenance-Related System Parameters
form to identify the product ID of the switch.