Avaya S8700 Maintenance Manual page 1280

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-224. Test #16 DIG-LINE Station Lamp Updates Test — Continued
Error
Code
Test Result
1392
ABORT
FAIL
PASS
Digital Station Audits Test (#17)
This is a series of six tests that are classified as audits. The media server sends
messages to the on-board microprocessor to perform the following tests. These
audits run only if the station is in-service.
Switchhook Inquiry test
according to the circuit pack's records. This inquiry is sent all the way to
the voice terminal.
Bad Scan Inquiry test
generated by certain events relating to the link's conditions. This can be an
indication of communications problems between the media server and
Digital Port circuit pack.
EPF/PTC Inquiry test
an up-link status message of the Electronic Power Feed (EPF) is sent.
Possible conditions are: EPF-on-ok, EPF-off, and EPF-no-load.
For TN754 (vintage 14 or later), TN754B, TN2136, TN2181, or TN2224, an
up-link status of the PTC is sent. Possible conditions are: PTC-on-ok,
PTC-off, and PTC-no- load.
ID Request test
station sends its configuration information and health information back.
This information is checked and a pass/fail result is provided.
8-558
Issue 1 May 2002
Description / Recommendation
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config
command (the display shows a "t" for the port).
2. If either list config or display port indicates that the port is not a TTI
port, escalate the problem. If both commands indicate that the port is a
TTI port, the abort is correct, and no action is necessary.
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
The message to light every station lamp was sent successfully to the port.
1. Observe the station lamps being lit when running the test. If all lamps
do not light, the other Digital Line test results may indicate related
problems that do not allow the lamps to light.
2. Investigate by using other Digital Line port tests, and by examining the
station, wiring, and connections.
This is an update of the media server's records
An up-link message is sent containing a count
For a TN413 or a TN754 (vintage 13 or earlier),
A request is made to the station for its status. The
Continued on next page