ETH-PT (Control LAN Ethernet)
TCP/IP PING Test (#1281)
This nondestructive test fails if every endpoint fails to respond. Use this test to
check the circuitry in the data path for a peer-to-peer IP layer connection.
Table 8-293. Test #1281 TCP/IP PING Test
Error
Test
Code
Result
Description / Recommendation
1, 2,
ABORT
Internal error
11
1. Retry the command at 1-minute intervals up to 3 times.
2. If the problem persists, escalate the problem.
7
ABORT
Destination unreachable.
1. Verify that there is a destination to ping in the routing table (list ip-route and
2. If there are no reachable destinations from this port (i.e., no routes
3. Escalate if the problem persists.
1005
ABORT
Incorrect test configuration.
1. Verify Ethernet link is in service (status port UUCSSpp or status link n).
2. Verify that Ethernet link is enabled (status port UUCSSpp or status link n
3. Verify routing table has reachable destinations.
4. Repeat the test.
5. If problem persists while the Ethernet link is in service and enabled,
1124
ABORT
Ethernet link is not enabled.
1. Verify that the Ethernet link is enabled (status port UUCSSpp, status link
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125
ABORT
Ethernet link not in service.
1. Verify Ethernet link is in service (status port UUCSSpp or status link n).
2. If the link is not in service, release the link using (release link n or release
3. Repeat the test.
4. Escalate if the problem persists.
555-233-143
look for destinations reachable through this ethernet port).
administered on ethernet), administer a route and retry.
or display data-module).
escalate the problem.
n, or display data-module).
port UUCSSpp).