Avaya S8700 Maintenance Manual page 1641

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

HYB-LINE (Hybrid Line)
Hybrid Line Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status
record contained in the processor. The lamp updates will run only if the station is
in service.
Table 8-355. Test #60 Hybrid Line Lamp Updates Test
Error
Test
Code
Result
Description / Recommendation
1
ABORT
A request for a remote station lamp update aborted even though every internal
resource was correctly allocated.
1. Look in the error log for Error Type 18 (port busied out) for this port. If this
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
3
ABORT
The station is in a ready for service or an out of service state. This may be due
to wiring or an unplugged or defective set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
2. If the port status is idle, then retry the command at 1-minute intervals up to
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
2. If either list config or display port indicate that the port is not a TTI port,
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
555-233-143
Error Type is present, release the port via the release port UUCSSpp
command or the release station extension command, and then run the
test again.
extension number of the port. Use the status station command to
determine the service state of the port. If the port is in use, wait until it is
idle before testing.
5 times.
(the display shows that the port is a TTI port) or the list config command
(the display shows a
t
for the port).
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct, and no action is necessary.
Continued on next page
Issue 1 May 2002
8-919

Advertisement

Table of Contents
loading

Table of Contents