DIG-LINE (Digital Line)
DIG-LINE Station Lamp Updates Test (#16)
This test lights all lamps on the terminal as specified. The lamp updates will run
only if the station is in-service. The status of the station is checked and the lamp
updates are blocked from taking place if the station is not in the in-service state.
This test does not affect the status of the Message Waiting lamp.
Table 8-224. Test #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test Result
ABORT
1
ABORT
3
ABORT
1000
ABORT
555-233-143
Description / Recommendation
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error type is present, then release the port via the release station
extension command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
Station may be in ready-for-service or out-of-service state.
1. Use status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port UUCSSpp to determine the station extension or
attendant number of the port. Use status station or status attendant
to determine the service state of the port. If the port is in use, wait until
it is idle before testing. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
2. If the port status is idle, then retry the command at 1-minute intervals up
to 5 times.
Continued on next page