Maintenance-Object Repair Procedures
Table 8-29. Test #35 Battery Feed Test — Continued
Error
Test
Code
Result
Description / Recommendation
PASS
The port's battery feed chip is able to provide power to the station equipment to
detect on-/off-hook, but may not be able to supply power for touch-tones. If
touch-tones are inoperative on this station, then replace the circuit pack
because this port is inoperative. User-reported troubles on this port should be
investigated by using other port tests, by examining station wiring, or by
examining the station.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Use the list config
2. If the board was found to be correctly inserted in step 1, issue the busyout
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
8-72
Issue 1 May 2002
command, and resolve any problems.
board command.
This should re-establish the linkage between the internal ID and the port. If
not, verify that a valid board is inserted.