Avaya S8700 Maintenance Manual page 816

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-37. Test #47 Loop Around and Conference Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7
ABORT
The port was seized by a user for a valid call.
1. Enter display port UUCSSpp to determine the station's extension. Enter
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test were not available. The port may be
busy with a valid call. (This could be a Music-on-Hold port.)
1. Enter display port UUCSSpp to determine the station's extension. Enter
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out-of-service.
1. Resolve TTR-LEV errors.
2. Resolve TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
1004
ABORT
The port has been seized for a valid call during the conference or noise test.
1. If the circuit pack is a TN742 of Vintage 10 or less, this test is not valid.
2. When the port is available for testing, retry the command at 1-minute
8-94
Issue 1 May 2002
status station extension to determine the service state of the port. If the
port is active, it will be unavailable for certain tests. Wait until the port is
idle before retesting.
status station extension to determine the service state of the port. If the
port is active, it will be unavailable for certain tests. Wait until the port is
idle before retesting.
repeat test at 1-minute intervals up to 5 times.
Otherwise, proceed with step 2.
intervals up to 5 times.
Continued on next page