Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-26. 24-Port Analog Line Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1(a)
40960
none
40975
40977
15(b)
Any
Audits and Updates
test (#36)
18
0
busyout station
extension
130(c)
None
257(d)
40973
none
513(e)
Station Present test
(#48)
769
Battery Feed test
(#35)
1025
Looparound test
(#161)
1281
Conference test
(#7)
1537
NPE Crosstalk test
(#6)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
Notes:
a. These are in-line errors and can only be resolved over time.
Aux Data 40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5
board.
8-64
Issue 1 May 2002
Alarm
On/Off
Level
Board
Any
Any
WARNING
ON
WARNING
ON
WARNING
OFF
MINOR
ON
2
WARNING
MINOR
ON
2
WARNING
MINOR
ON
2
WARNING
MINOR
ON
2
WARNING
th
incoming call will cause an inline error from the
Test to Clear Value
test port UUCSSpp sh r 1
release station extension
test port UUCSSpp sh
test port UUCSSpp sh r 2
test port UUCSSpp sh r 2
test port UUCSSpp l r 2
test port UUCSSpp l r 2
test port UUCSSpp l r 2