Avaya S8700 Maintenance Manual page 1693

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ISDN-LNK (ISDN-PRI Signaling Link Port)
A problem with an ISDN-LNK will affect every associated B channel since, without
it, no call-control information can be conveyed to the far-end switch or to a
terminal adapter. Stable calls may remain operational, but no new calls can be
placed. In turn, the ISDN-LNK depends on the:
TN464C/D UDS1 Interface circuit pack where it resides
packet bus that provides the link to the processor
If there are problems with the ISDN-LNK, also investigate the TN464C/D UDS1
Interface circuit pack (UDS1-BD) and the packet bus (PKT-BUS).
Hardware Error Log Entries and Test to Clear
Values
Table 8-383. ISDN-PRI Signaling Link Port Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
18 (a)
0
busyout port UUCSSpp
130 (b)
None
1537 (c)
46210
1793 (d)
3585 (e)
46222
3841 (f)
46211
3842 (g)
46223
3843 (h)
Signaling Port LAN
Loop-Back test (#939)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
pp is 24 for 24-channel interfaces and 16 for 32-channel interfaces.
Notes:
a. The D channel is demand busied out. No calls can be made over this
D channel.
b. This Error Type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
555-233-143
Alarm
On/Off
Level
Board
Any
Any
2
WARNING
OFF
WARNING
ON
WARNING
OFF
MINOR
ON
Issue 1 May 2002
Test to Clear Value
2
test port UUCSSpp
2
release port UUCSSpp
2
test port UUCSSpp
test board UUCSS l
2
test port UUCSSpp
l
8-971

Advertisement

Table of Contents
loading

Table of Contents