BRI-SET, ASAI-ADJ, BRI-DAT
Table 8-156. Test #627 BRI Remote Loop Back
Error
Test
Code
Result
Description / Recommendation
1000
ABORT
Could not seize the endpoint or B channels for test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1005
ABORT
The endpoint's MIMs Supported field is administered to "no."
1. Use the change station extension command to change parameter only if
1113
ABORT
The signaling link between the switch and the endpoint is down.
1. Use the test port PCSSpp long command to clear any errors that prevent
2. Examine the results of the Signaling Link Status test (#626) that is run as
3. If the XID test (#628) continues to abort, escalate the problem.
1139
ABORT
The EPN's packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute the test port long PCSSpp command,
1141
ABORT
The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack) Maintenance
2. If step 1 does not resolve the problem, escalate to the next tier.
555-233-143
the endpoint documentation reflects support for ISDN-BRI Management
and Maintenance Procedures.
establishment of the signaling link.
part of this command. If this test aborts or fails, follow the repair procedure
for Test #626.
and review the results of the BRI Port Local LAN Loop Around test (#618)
to verify the repair.
documentation.