DIOD-TRK (DIOD Trunk)
Error Log Entries and Test to Clear Values
Table 8-232. DIOD Trunk Error Log Entries
Aux
Error Type
Data
Associated Test
1
0
0
Any
15 (b)
any
Port Audit Update test (#36)
18
0
busyout trunk grp/mbr
769 (a)
57392
None
1537
Dial Tone test (#0)
1793
Looparound and Conference
test (#33)
2049
NPE Cross Talk test (#6)
2561 (a,d)
57345
None
2817 (a,e)
57393
None
3073 (a,c)
57376
None
3073 (a,c)
57424
None
3585 (a,c)
57424
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is upgraded to a
Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Notes:
a. These are in-line errors that have no specific test associated with them.
See
Table 8-233
b. This is a software audit error and does not indicate any hardware
malfunction. Run the short test sequence, and investigate associated
errors.
555-233-143
Alarm
Level
Any
WARNING
MAJOR
MINOR
WARNING
MAJOR
MINOR
WARNING
MAJOR
MINOR
WARNING
MAJOR
MINOR
WARNING
for an explanation and appropriate action.
On/Off
Test to Clear
Board
Value
Any
test port sh
release trunk
ON
2
ON
test port long r 2
2
ON
test port long r 3
2
ON
test port long r 3
2
Issue 1 May 2002
8-575