DS1 CONV-BD
Table 8-276. Test #790 DS1 Facilities Connectivity Loop-Back Test
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Timed out while waiting for a response from the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2300
ABORT
The downlink message necessary to run this test could not be sent.
2301
ABORT
The timer could not be set before sending the downlink message necessary to
run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2316
ABORT
Fiber link is not administered. Administer the DS1 CONV fiber link via the add
fiber-link command.
2321
ABORT
DS1 CONV circuit pack is not busied out. Busyout the DS1 CONV circuit pack
via the busyout board command.
2332
ABORT
With this system configuration (unduplicated PNC), the test was aborted
because it cannot be run at the far end when there is only one DS1-FAC
available. (The link would be lost, and no test results would be seen at the
media server.) Run the test at the other end of the DS1C complex.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.