ETR-PT (Enhanced Tone Receiver Port)
Table 8-298. Test #43 Tone Detector Audit/Update Test — Continued
Error
Test
Code
Result
Description / Recommendation
FAIL
Hardware audit failed.
1. Use list configuration carrier to get the board type and location. If the
2. Execute three commands: busyout board UUCSS, reset board UUCSS,
3. Test the board (test board UUCSS long).
4. If the test passes, terminate the repair process. If the test fails, replace the
5. Check to see if the board is duplicated (list cabinet and status
6. If the board is not duplicated, use test tone UUCSS long to resolve the
7. If all tests pass and the alarm does not resolve, retest (test tone UUCSS
8. If the test passes, terminate the repair process. If it fails, replace the circuit
9. If the board is duplicated, switch to the standby side (set tone/set
10. Test the alarmed board (test tone UUCSS long). This resets the board and
11. If all tests pass and the alarm does not resolve, retest with test tone
12. If the test passes, terminate the repair process. If it fails, replace the
PASS
The ETR port has passed the sanity inquiry.
555-233-143
board is TN744, then do steps 2–4; if it is TN2182/TN2312AP, do steps
5–12.
and release board UUCSS. Reset is required to reload RAM associated
with the TN744's DSPs. This will take all eight tone detector ports out of
service for a few seconds. Only four of the eight would be out of service
due to the alarm. (There are four tone detectors on each of the two DSPs.)
Other than the unlikely potential of running out of tone detector resources
in the switch, there is no other effect when the board is reset.
board. Follow the procedures in TONE-BD.
port-network on the affected PN.)
error. The long test resets the board and is required to reload on-board
RAM associated with the TN2182's/TN2312AP's DSPs. The effect is that
tone detectors are taken out of service momentarily and tones are
removed from the TDM bus for about 10 seconds. This means no dial
pulses or touch tones during this interval, which probably will not affect
calls in progress, but could cause a call origination to abort or cause a user
to not get dial tone when going off hook.
long clear).
pack at the customer's convenience. Follow the procedures in TONE-BD.
ipserver-interface).
is required to reload on-board RAM associated with the
TN2182's/TN2312AP's DSPs.
UUCSS long clear.
board. Follow the procedures in TONE-BD.
Continued on next page
Issue 1 May 2002
8-761