Maintenance-Object Repair Procedures
Table 8-154. ISDN-BRI CAUSE VALUES
Error
Code
Test Result
1
34
No circuit or
channel
available
42
Switch
Equipment
Congestion
8-364
Issue 1 May 2002
Description / Recommendation
Another station is using requested channel on the
BRI-PORT. (Not applicable for ASAI or Avaya adjuncts.)
For BRI endpoints:
1. Try to originate a call to or from this port.
2. If the error persists, busyout and release the port.
3. If the problem still persists, replace stations on the port.
4. If the problem still persists, escalate to the next tier.
A resource on the switch is unavailable for a call. For BRI
endpoints: This cause value is not logged. For ASAI or
Avaya Adjuncts: This condition means that there are no
available trunks for an outgoing call request.
1. Verify that the adjunct is administered to support the
trunk capabilities of the switch.
2. Investigate trunk group status by issuing status trunk
commands from the SAT or by requesting a trunk group
query or queries from the adjunct.
3. Perform trunk diagnostic procedures outlined in this
manual.
4. If step 3 does not resolve the problem, escalate to the
next tier.
Switch takes control to limit received traffic. For BRI
endpoints: This cause value is not logged. For ASAI or
Avaya Adjuncts:
1. Refer to the CallVisor protocol reference manual.
2. If step 1 does not resolve the problem, escalate to the
next tier.