Avaya S8700 Maintenance Manual page 1212

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-197. Data Line Port Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1
Digital Looparound
test (#171)
15(a)
Any
Audit Update test
(#36)
18
0
Busyout port
UUCSSpp
130 (b)
None
257
Conference Circuit
test (#7)
513
NPE Crosstalk test
(#6)
769(c)
40983
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate errors.
b. Indicates the circuit pack has been removed or has been insane for more
than 11-minutes. To clear the error, reseat or replace the circuit pack.
c. Error type 769 indicates that the data line circuit pack found an error in the
transmit/receive circuitry of an administered data line when the circuit pack
was inserted. Perform the following:
1. Enter busyout board UUCSS for the circuit pack on which the port
2. Enter reset board UUCSS. Check the Error Log to determine
3. Enter release board UUCSS.
8-490
Issue 1 May 2002
Alarm
Level
Any
MINOR
WARNING
WARNING
MINOR
MINOR
resides.
whether Error Type #769 is logged again for DAT-LINE. Make sure
that the Active Alarms Only field is set to n.
If Error Type #769 reappears, replace the data line circuit pack. If
not, proceed to step 3.
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp sh r 1
ON
test port UUCSSpp s r 2
OFF
rel port UUCSSpp
ON
test port UUCSSpp sh
ON
test port UUCSSpp l r 2
ON
test port UUCSSpp l r 2
555-233-143

Advertisement

Table of Contents
loading

Table of Contents