CO-DS1 (DS1 CO Trunk)
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
Interface circuit pack to assure that the trunk's translation is correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk.
Table 8-181. Test #36 Port Audit and Update Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test were not available. The port may be
busy with a valid call.
1. Issue display port UUCSSpp to determine the trunk group/member
2. If the port status is active but the port is idle (no calls), check the error log
3. If the port status is idle, retry the command at 1-minute intervals up to 5
1006
ABORT
The DS1 CO trunk is out of service.
1. Use status trunk to verify that the trunk is out of service.
2. If the trunk is out of service, determine why.
3. If it is OK to put the trunk back in service, issue the release trunk
2000
ABORT
Response to the test was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
FAIL
Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Trunk translation has been updated successfully. The current trunk states kept
in the DS1 Interface circuit pack and switch software are consistent. If the
trunk is busied out, the test will not run but will return PASS. To verify that the
trunk is in-service:
1. Enter status trunk to verify that the trunk is in-service. If the trunk is
2. Enter release trunk to put the trunk back into in-service.
3. Retry the test command.
555-233-143
number of the port. Use the status trunk command to determine the
service state of the port. If the port is active, wait until it is idle before
testing.
for error type 1025. The port may be locked up.
times.
command to put the trunk back in service, and then retry the test.
in-service, no further action is necessary. If the trunk is out-of-service.