Maintenance-Object Repair Procedures
Table 8-235. Test #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
Description / Recommendation
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Enter display port UUCSSpp to determine the trunk group/member
2000
ABORT
Response to the test was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port was found to be transmitting in error. This causes
noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated by using other port tests and by examining
trunk or external wiring.
8-580
Issue 1 May 2002
number of the port. Use the status trunk command to determine the
service state of the port. If the port is in use, wait until it is idle before
retesting.
Continued on next page