Advertisement

CO-DS1 (DS1 CO Trunk)
Notes:
a. Error Type 1—Aux Data 57408—No tip ground is detected on an outgoing
call.
Aux Data 57487—PBX could not get "loop close" signal.
The DS1 Interface circuit pack detected a hardware fault. These errors will
cause Dial Tone Test #314 to run and are only considered a problem if the
Dial Tone test fails (in which case Error Type 1025 will also show up). In
this case, the trunk may be put in the ready-for-service state (shown as
"disconnected" by the status command), which allows only incoming calls.
Run Dial Tone Test #314, and follow the procedures.
b. Error Type 15—This is a software audit error that does not indicate any
hardware malfunction. Run short test sequence, and investigate
associated errors (if any).
c. Error Type 18—System Technician has busied out the trunk to the
out-of-service state. No calls can be made on this trunk except Facility
Access Test Calls. For details on this feature, see
section in
d. Error Type 130—This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or replace the circuit pack.
e. Error Type 257—The DS1 Interface circuit pack detects a hardware fault.
Aux Data 57392 indicates no external release on PBX disconnect.
f. Error Type 513—The DS1 Interface circuit pack detects a hardware fault.
Aux Data 57393 indicates belated external release on PBX disconnect.
g. Error Type 769—The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type:—57484, fault is
detected on tip/ring.
555-233-143
Chapter 5, ''Additional Maintenance
''Facility Test Calls''
Procedures''.