Avaya S8700 Maintenance Manual page 1579

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

FIBER-LK (Fiber Link)
Table 8-328. Test #759 Configuration Audit — Continued
Error
Test
Code
Result
Description / Recommendation
218
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 18. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 3329, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 3329, replace the
219
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 19. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 3585, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 3585, replace the
220
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 20. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 3841, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 3841, replace the
555-233-143
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 18.
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 19.
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 20.
4-19. This should
4-19. This should
4-19. This should
Continued on next page
Issue 1 May 2002
8-857

Advertisement

Table of Contents
loading

Table of Contents