Maintenance-Object Repair Procedures
System Technician-Demanded Tests:
Descriptions and Error Codes
The command to test the ISDN-LNK MO is test port UUCSSpp where pp is 24 for
24-channel interfaces and 16 for 32-channel interfaces.
Order of Investigation
Signaling Port LAN Loop-Back test (#939)
Signaling Link Board check (#643)
1.
D = Destructive; ND = Nondestructive
Signaling Link Board Check (#643)
This test checks the health of the TN464C/D UDS1 Interface transporting the
ISDN-PRI Signaling Link port.
Table 8-381. Test #643 Signaling Link Board Check
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with this
D-channel port is detached from the circuit pack. This is normal when the
rollabout video feature is enabled. To complete a test on this port:
1. Re-attach the disconnected PRI terminal adapter
2. Disable the rollabout video feature on this board by entering change ds1
8
FAIL
The UDS1 TN464C/D circuit pack is not in service.
1. Check the Hardware Error Log for entries logged against UDS1-BD, and
PASS
The UDS1 Interface circuit pack transporting the ISDN-PRI Signaling Link Port
is in service.
8-968
Issue 1 May 2002
UUCSS and set the "Alarm when PRI Endpoint Detached?" field to "y."
consult "UDS1-BD" for repair procedures.
Short Test
Long Test
Sequence
Sequence
X
X
X
1
D/ND
D
ND
555-233-143