Maintenance-Object Repair Procedures
Signaling Path PING Test (#1373)
This test is nondestructive.
The test determines the local C-LAN through which the signaling originates and
the endpoint's IP address. It then requests the local C-LAN to execute a PING on
the endpoint's address. If the PING is successful, the test passes, if the PING is
not successful, the test fails.
NOTE:
Multiple failures of this test can take the H.323 IP Station out of service.
This test checks the circuitry involved in the data path of a peer-to-peer IP layer
connection.
This nondestructive test runs due to in-line errors, during periodic and schedule
maintenance, and on demand.
Table 8-346. Test #1373 Signaling Path PING Test
Error
Test
Code
Result
Description / Recommendation
2100
ABORT
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1003
FAIL
Ping to the destination failed.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Investigate any C-LAN ethernet port errors.
8-900
Issue 1 May 2002
Continued on next page
555-233-143