Avaya S8700 Maintenance Manual page 832

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-42. Test #35 Battery Feed Test — Continued
Error
Test
Code
Result
Description / Recommendation
1392
ABORT
This port is currently a TTI port and the test does not execute on it.
1. Verify that the port is a TTI port:
2. If both commands indicate that the port is a TTI port, the abort is correct for
3. If either command indicates that the port is not a TTI port, escalate the
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
FAIL
The port's battery feed chip is unable to supply sufficient power to the terminal
equipment. This test result might be marginal, and the terminal equipment may
be operating satisfactorily.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, determine whether the customer is experiencing
PASS
The port's battery feed chip is able to provide sufficient power to the station
equipment to detect on-/off-hook, but may not be able to supply power for
touch-tones.
1. If touch-tones are inoperative on this station, replace the circuit pack
2. Investigate user-reported troubles on this port by running other port tests,
8-110
Issue 1 May 2002
Enter the display port UUCSSpp command (the display shows
that the port is a TTI port).
Enter the list configuration command (the display shows a t
for the port).
the test, and no action is necessary.
problem.
problems on this line. Replace the circuit pack only if the customer is
experiencing problems.
because this port is inoperative.
by examining station wiring, or by inspecting the station.
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents