Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-133. ATM-WSP Error Log Entries
Error
Aux
Type
Data
Associated Test
0
0
Any
18 (a)
MO busied out
257 (b)
Active WSP (#1401)
513 (c)
WSP Link Status (#1400)
769 (d)
WSP #
WSP Priority Error
1025 (e)
WSP Error
1.
There are no system technician-demanded Tests associated with this MO. The tests listed in this column are
tests run by system software.
Notes:
a. Error Type 18 — indicates that the ATM WSP has been busied out with the
busyout atm wsp command. To resolve this error, check for any other
errors that would require that the WSP be made maintenance busy. Clear
every related alarm. After every related alarm is clear, or if there are no
other alarms, release the ATM circuit pack using the release atm wsp
command.
b. Error Type: 257 — indicates that the WSP has become active. When a
WSP takes over, the error becomes active, and causes an alarm condition.
This error is not applicable for the main server. Use the following
procedures to return the system to normal operation:
1. Run status atm wsp on the active WSP to verify that the main
2. If the main server or the higher-priority WSP is "up," then run reset
3. Wait a few minutes, and run list sys-link on the main server or
8-304
Issue 1 May 2002
1
server or a higher-priority WSP that you want to be in control is "up."
system 2. The active WSP should relinquish control.
higher-priority WSP to verify that the EAL and ACL system links are
"up."
Alarm
On/Off
Level
Board
Any
MAJOR
OFF
MINOR
OFF
MINOR
OFF
WARNING
OFF
Test to Clear Value
release atm wsp
reset system 2