ANL-16-L (16-Port Analog Line)
Error Log Entries and Test to Clear Values
Table 8-19. 16-Port Analog Line Error Log Entries
Error
Aux
Type
Data
1
0
0
1(a)
40960
40975
40977
15(b)
Any
18
0
130(c)
257(d)
40973
513(e)
769
1025
1281
1537
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
Notes:
a. These are in-line errors and can only be resolved over time.
Aux Data 40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5
Aux Data 40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure in the
terminal equipment or the type of terminal has a low ringer impedance.
555-233-143
Associated
Alarm
Test
Level
Any
Any
none
Audits and
Updates test
(#36)
busyout
WARNING
station
extension
None
WARNING
none
Station
WARNING
Present test
(#48)
Battery Feed
MINOR
test (#35)
WARNING
Looparound
MINOR
test (#161)
WARNING
Conference
MINOR
test (#7)
WARNING
NPE
MINOR
Crosstalk test
WARNING
(#6)
th
incoming call causes an inline error from the board.
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp sh r 1
ON
release station extension
ON
test port UUCSSpp sh
OFF
test port UUCSSpp sh r 2
ON
test port UUCSSpp sh r 2
2
ON
test port UUCSSpp l r 2
2
ON
test port UUCSSpp l r 2
2
ON
test port UUCSSpp l r 2
2
Issue 1 May 2002