Avaya S8700 Maintenance Manual page 708

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Commands
!
WARNING:
Since the clear long option clears every counter if the test passes, it is
possible for firmware counters to be cleared even though a problem exists.
In some cases customer service might degrade since calls may be routed
over defective equipment.
Output
The following example shows the output for the test pkt port-network 1
command. The responses display on a test-by-test basis with one line of data for
each test result.
test pkt port-network 1
Port
Maintenance Name
PN 01
PKT-BUS
PN 01
PKT-BUS
PN 01
PKT-BUS
Command successfully completed
Field Descriptions
Port
Maintenance
Name
Alt.
Name
Test No
Result
Error Code
7-452
Issue 1 May 2002
TEST RESULTS
Alt. Name
A port network number (1 – 44).
The name of maintenance object being tested.
Not applicable.
The test being executed.
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Numeric code explaining why the release failed or aborted. Refer to the
detailed list of the codes by test number for each MO.
Test No.
Result
571
PASS
572
PASS
573
PASS
Error Code
555-233-143

Advertisement

Table of Contents
loading

Table of Contents