test pkt

test pkt
The test runs a series of tests on the packet bus of the specified PN.
Table 7-57. test pkt command parameters
Action/
Object
Qualifier
test pkt
PN#
port-
short
network
long
repeat#
clear
schedule
1.
If no alarms are registered against the maintenance object, then the test sequence is run only once. The long
clear option forces a clear of every alarm if no errors are encountered during testing. The short clear option
only clears alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
2.
Refer to the Report Scheduler and System Printer feature specification for more details.
555-233-143
Qualifier Description
The packet bus to be tested:
nn (1 – 44)
Option for a brief series of
nondestructive diagnostic
tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in
the sequence is repeated (1 –
100)
This option causes the test
sequence (short or long) to
repeat until the alarm (if any) is
cleared or a single test in the
1
sequence fails.
Command is validated and
then a scheduling form
displays to schedule execution
of the command. The
command is then placed in the
command queue and is
executed at the specified time.
The information displayed by
the command is sent to the
system printer instead of the
2
screen.
Examples:
test pkt port-network 1 l
test pkt port-network 2 sh r 2
test pkt port-network 2 sh
schedule
test pkt port-network 1 l r 25
test pkt port-network 2
test pkt port-network 1 c
Permissions
Defaults
init
Test
inads
Sequenc
craft
e = short;
Repeat =
1
Issue 1 May 2002
Feature
Interactions
none
7-451

Advertisement

Table of Contents
loading

Table of Contents