Avaya S8700 Maintenance Manual page 732

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. For example,
by clearing error codes associated with the AC Power Query test (#78), you may
also clear errors generated from other tests in the testing sequence. Refer to the
appropriate sections of this chapter for descriptions of each test.
Order of Investigation
Battery & Battery Charger Query test (#5)
AC Power Query test (#78)
Power Unit Query test (carrier E) (#127)
Power Unit Query test (carrier D) (#127)
Power Unit Query test (carrier A) (#127)
Power Unit Query test (carrier B) (#127)
Power Unit Query test (carrier C) (#127)
Emergency Transfer Query test (#124)
Cabinet Temperature Query test (#122)
External Alarm Lead Query test (#120)
Analog Ring Generator Initialization test (#117)
Analog Ring Generator Query test (#118)
1.
D = Destructive; ND = Nondestructive
8-10
Issue 1 May 2002
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
D/ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
555-233-143