Avaya S8700 Maintenance Manual page 731

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

AC-POWER
AC-POWER for DC-Powered Systems
MO's Name (in
Alarm Log)
AC-POWER
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC).
NOTE:
In a DC-powered multicarrier cabinet, the AC-POWER MO exists, but
serves no functional purpose. Because the system cannot determine the
type of power used, the AC-POWER test should always pass or abort. The
maintenance strategy for power components in DC cabinets is described in
''CARR-POW (Carrier Power Supply)'' on page
S8700 Multi-Connect supports three different cabinet types for EPNs: multicarrier
cabinets (MCCs), single-carrier cabinets (SCCs), and 19-inch rack mounted
cabinets. Every type may be powered by either an AC or DC power source.
Environmental maintenance differs according to a cabinet's type and its power
supply.
Error Log Entries and Test to Clear Values
Table 8-3. AC Power Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
513
Any
AC Power Query test (#78)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
555-233-143
Alarm
Level
Initial Command to Run
WARNING
test environment UU
Alarm
Level
Any
WARNING
Full Name of MO
1
AC Power
8-393.
On/Of
f
Board
Test to Clear Value
Any
test environment UU sh r 1
OFF
test environment UU sh r 1
Issue 1 May 2002
8-9

Advertisement

Table of Contents
loading