LOG-SVN (Login Security Violation)
Error Log Entries and Test to Clear Values
Table 8-404. Security Violation Notification Error Log Entries
Error
Aux
Type
Data
Associated Test
1-15
None
None
General Information about log-svn error log entries:
a. The number (1–15), that appears in the error type field, corresponds to the
location of the login in the internal login data structure.
b. The Alt Name field on the alarm report indicates the login ID associated
with the security violation and major alarm.
c. These errors/alarms are associated with a number of failed attempts to
access the system management/maintenance interface using an Avaya
services login ID that meet or exceed the customer administered threshold
parameters. The associated alarm is immediately raised as a major alarm.
d. The affected login ID will be disabled as a result of detection of the security
violation, unless it is the system's last enabled INADS-type login. The
provision to disable a login ID following detection of a security violation
involving that login ID is administrable on a login ID basis.
e. The enable login command is used to both enable a login that has been
disabled, and to retire any login security violation alarms associated with
the login ID.
f. Use of the enable login command to enable a login and/or retire alarms
must be executed using a login ID with greater service level hierarchy
permissions.
g. Access to the enable login command is controlled through the Administer
Permissions field on the Command Permission Categories form. This field
(Administer Permissions) must be set to "y" to access the enable login
command.
h. The Port alarm report field will set to the port where the final invalid login
attempt, involving the alarmed login ID, was detected. Valid port values for
G3i products include:
— MGR1 — Dedicated Manager 1 or G3 MT (management terminal)
— NET-n — Network controller's dial-up port
— INADS — Alarm receiver's port
— EPN — EPN's maintenance EIA port
— EIA — Other EIA port
555-233-143
Alarm
Level
Major
connection
On/Off
Board
Test to Clear Value
OFF
enable login login-ID
Issue 1 May 2002