Test Isdn-Testcall - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

test isdn-testcall

test isdn-testcall
test isdn-testcall group#/member# [minutes num-minutes] [schedule]
The test isdn-testcall command starts an outgoing ISDN-PRI test call using the
asynchronous method.
Only 1 ISDN trunk in each port network can be tested at one time. The maximum
number of asynchronous outgoing test calls that can be run simultaneously
depends on the number of Maintenance/Test circuit packs in the system.
For more information, see Test #258 under
page
8-989.
Parameters
group#/member#
minutes #
For more information, see
Examples
test isdn-testcall 78/2 minutes 10
Output
PASS – The test call was successfully initiated.
Result
ABORT – Resources were not available (for example, a B channel or
Maintenance/Test circuit pack).
FAIL – An outgoing test call could not be initiated.
555-233-143
Specify the trunk over which to originate the test call.
Specify the duration of the test call in minutes from 1 to 120. The duration
defaults to 8.4 or 9.6 seconds.
''Common Input
''ISDN-TRK (DS1 ISDN Trunk)'' on
Parameters''.
Issue 1 May 2002
7-443