Avaya S8700 Maintenance Manual page 686

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Commands
Parameters
physical location
In addition to entering the word "physical" the system technician must specify
the physical location. For an administered external device alarm analog line
port, a "physical location" represents the physical position of the port to be
tested and is entered as UUcSSpp where "UU" represents the cabinet
number (1-MAX_CABS), "c" represents the carrier, "SS" represents the slot
position, and "pp" represents the circuit.
Since the "maintenance board" alarm connections connect to control carrier
boards that are in unnumbered slots, the standard port format cannot be used
to designate these alarm connections. The special ports UUmajor and
UUminor are used designate the major or minor maintenance board alarm
connection for cabinet UU.
The "all" location is used to test every administered external device's alarm
port on analog line boards and maintenance boards.
repeat number
The "number" specifies how many times the "test physical location" is to be
repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the alarm
(if one exists against the MO) is cleared or a single test in the sequence fails.
If no alarms are registered against the maintenance object then the test
sequence will be exercised only once.
schedule
When the "schedule" option is specified, the command is validated and then a
scheduling form is displayed to allow the technician to schedule execution of
the command. The command is then placed in the command queue and is
executed at the specified time. The information displayed by the command is
sent to the system printer instead of the screen. Refer to the Report
Scheduler and System Printer feature specifications [1] for more details.
Examples
test eda-external-device-alrm all
test eda-external-device-alrm all schedule
test eda-external-device-alrm physical 1major r 10
test eda-external-device-alrm physical 2c1101 c
7-430
Issue 1 May 2002
NOTE:
The special locations
UUmajor
the major or minor Maintenance circuit pack alarm connection for
cabinet UU (depends upon the auxiliary connector of the Port
Network). Thus, both a "major" and "minor" port can be administered
with major, minor, or warning alarms.
and
designate the name of
UUminor
555-233-143