Maintenance Commands
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
Port
Maintenance
Name
Alt.
Name
Test No
Result
Error Code
For the following output example, assume that the board in cabinet 1, carrier c,
slot 7 is a TN767E DS1 board. The command that was entered was test
ds1-loop 1c07.
test ds1-loop 01C07 ds1/csu-loopback-tests
Port
Maintenance Name
01C07
DS1-BD
01C07
DS1-BD
01C07
DS1-BD
Command successfully completed
Feature Interactions
Loopback or span tests will not be allowed on DS1 boards unless the board has
been busied out.
Only one of the CPE loopback jack, far-end CSU, one-way span, or DS1/CSU
loopback tests may be active at any given time on a DS1 span.
7-428
Issue 1 May 2002
The port address (cabinet-carrier-slot-circuit) of the maintenance object
that is being tested.
The type of maintenance object that is being tested.
The alternate means of identifying the maintenance object.
The actual test that is being executed.
The result of the individual test – PASS, ABORT, FAIL, NO BOARD,
DISABLED, EXTRA BD.
A system-generated number that tells why the release failed or aborted. A
detailed list of the codes according to "Test No." is provided for each MO.
TEST RESULTS
Alt.
Name Test No.
Result
1209
PASS
1210
PASS
1211
PASS
Error Code
555-233-143